HVPA Model Identification
HVPA HP
Special Option Code
Electric Heat (kW)
000 = No Heat 040 = 4 kW 050 = 5 kW 060 = 6 kW 090 = 9 kW 100 = 10 kW 120 = 12 kW 150 = 15 kW
Power Supply
A = 208/230V, 1 Ph, 60 Hz C = 208/230V, 3 Ph, 60 Hz D = 460V, 3 Ph, 60 Hz
System Type
Heat Pump
Nominal Cooling*
24 = 24,000 BTUH 30 = 30,000 BTUH 36 = 36,000 BTUH 42 = 42,000 BTUH 49 = 49,000 BTUH 60 = 60,000 BTUH
High Efficiency Vertical Package
Series
R = Electric Reheat Dehumidification U = Scroll Compressor G = HGR (Hot Gas Reheat)
Ventilation Code
N = 0-15% fresh air with manual damper, no presure relief
Y = 0 to 450 cfm* of outside air, field adjustable, manual damper, no pressure relief
Z = 0 to 450 cfm* of outside air, field adjustable, manual damper, includes pressure relief
B = Motorized two position damper (open & closed) capable of 0 to 450 cfm* of outside air, includes pressure relief
C = Economizer - 100% rated airflow of outside air used for cooling when outside conditions are suitable
H = GreenWheel
®
Energy Recovery Ventilator
Q = GreenCube
®
ERV
J = PowerVent with motorized damper. 0-450 cfm of outside air
••S
R410-A Refrigerant
Refrigerant
Two-Stage Compressor
Serial Number Date Code
A = January
B = February
C = March
D = April
E = May
F = June
G = July
H = August
J = September
K = October
L = November
M = December
L = 2000
M = 2001
N = 2002
P = 2003
R = 2004
S = 2005
T = 2006
U = 2007
V = 2008
Y = 2009
Z = 2010
A = 2011
B = 2012
C = 2013
1.2 Air Flow, Weights and Filter Sizes.
Table 1a. Air Flow (Cubic Feet per Minute) AVPA
MODEL
External Static Pressure (WET COIL)
0.10 0.20 0.25 0.30 0.40 0.50
AVPA24 860 810 740 670
AVPA30 1100 1000 960 920 810
AVPA36 1310 1220 1185 1150 1060
AVPA42 1650 1585 1520 1450 1360
AVPA48 1900 1830 1760 1700 1620
AVPA60 1900 1830 1760 1700 1620
Air flow ratings of 208-230v. Units are at 230v. Air flow ratings of 480 v. units are at 460 volts. Operation of units at a different
voltage from the rating point will affect air flow.
Table 1b. Air Flow (Cubic Feet per Minute) HVPA & HVPSA
MODEL
External Static Pressure (WET COIL)
0.10 0.20 0.25 0.30 0.40 0.50
HVPA24 800 770 725 680 600 500
HVPA30 1200 1100 1050 1000 900 800
HVPA36/HVPSA36 1290 1170 1115 1060 1000 920
HVPA42/HVPSA42 1500 1360 1295 1230 1160 1070
HVPA48/HVPSA48 1900 1800 1700 1600 1500 1350
HVPA60/HVPSA60 2200 2100 2000 1900 1800 1650
Air flow ratings of 208-230v. Units are at 230v. Air flow ratings of 480 v. units are at 460 volts. Operation of units at a different
voltage from the rating point will affect air flow.
Table 2a. Ship Weight (lbs) - Model AVPA
MODEL 24 30/36 42 48 60
Classic with "N" Ventilation Conguration 285 375 515 545 590
Classic with "Y", "Z", "B", "J" & "C"
Ventilation Conguration
315 405 545 575 590