5 AVPA & HVEA PDS 4/2012 rev.3
Accessories (cont’d)
Security Cages.
Deters theft of the
air conditioner and
components. Constructed
of1”by11gaugesquare
tubeand3/4”,#9
expanded metal. Hinges
and latch are made
from steel plate. The
complete cage is powder
coated for longevity and
to match the color of
Marvair air conditioners.
Field installed.
Options
The ComPac
®
I and ComPac
®
II air conditioners
were designed and are built to stringent requirements
of the communications/electronic shelter. Applications
occur that have special requirements. Numerous
options are available for the ComPac I and ComPac II
air conditioners that meet these special needs.
Hard Start Kit - Used on single phase equipment to
give the compressor higher starting torque under low
voltage conditions. (Field installed only) (Note: Not
recommended for use on scroll compressors.)
Dehumidification – ComPac
®
I and ComPac
®
II A/C
Allows the electric heat to operate simultaneously
with cooling. See Dehumidification Application
Bulletin for details. Note: The electrical characteristics
and requirements of air conditioners with the
dehumidification option are different from standard
air conditioners. Refer to the appropriate Summary
Rating Charts for the electrical characteristics of units
with Electric Reheat.
Coastal Environment Package ComPac
®
I A/C
only – Recommended for units to be installed near
an ocean or on seacoast. Includes corrosion resistant
fasteners, sealed or partially sealed condenser fan
motor, protective coating applied to all exposed
internal copper and metal in the in the condenser
section and an impregnated polyurethane on the
condenser coil. See Coastal Environmental Technical
Bulletin for more details.
External Low Noise Blower (ELNB) ComPac
®
I
and ComPac
®
II A/C A field installed kit that
consists of a condenser air hood, centrifugal blowers,
controls and a compressor jacket to reduce the
sound level by up to 6 dbA of Marvair ComPac air
conditioners. Available for models AVP30-60. See
External Low Noise Blower Product Data Sheet for
details.
ComPac
®
II Air Conditioner Transition Curb
ComPac II A/C only – A sheet metal curb that
enables a 3-1/2, 4 or 5 ton ComPac II air conditioner
to replace a 2-1/2 or 3 ton ComPac II unit. Curb
transitions supply and return openings of the 3-1/2, 4
and 5 ton units to the smaller openings.
Economizer Damper Control ComPac
®
II A/C
only – A minimum position potentiometer that can
be adjusted to prevent the economizer damper
from closing completely. This control ensures that
whenever the evaporator fan is operating, fresh air is
being introduced into the building. Factory installed.
Hot Gas By-pass ComPac
®
I A/C Only – Used
in specialty applications; i.e., Magnetic Resonance
Imaging (MRI) buildings, to prevent magnetic voltage
disturbance caused by compressor cycling. Hot
gas by-pass option packages are available to allow
operation to 20°F (-7°C). Please refer to Hot Gas
By-pass Application Bulletin for details. Not available
on the AVPA24.
High FiltrationUnits are built with larger
blowers/motors for use with higher efficiency filters
with MERV ratings of 11, 13 and 14 when tested
to ASHRAE 52.2. Units with economizers have a
prefilter on the outside air.
Color - ComPac
®
I and ComPac
®
II air conditioners
are available in five different cabinet colors -the
standard Marvair
®
beige, white, gray, brown and
dark bronze. The standard cabinet’s sides, top and
front panels are constructed of 20 gauge painted
steel. As an option, these panels can be built of
16 gauge steel in beige & gray or .050 stucco
aluminum. When the 16 gauge painted steel or the
aluminum is used, only the side, top and front panels
are 16 gauge or aluminum. Contact your Marvair
representative for color chips. The cabinet can also
be constructed of type 316 stainless steel. Two
stainless steel cabinet constructions are available-
the complete cabinet, including most internal sheet
metal or only the exterior sheet metal.
Protective Coil Coatings - Either the condenser
or evaporator coil can be coated, however, coating
of the evaporator coil is not common. For harsh
conditions, e.g., power plants, paper mills or sites
were the unit will be exposed to salt water, the coil
should be coated. Note: Cooling capacity may be
reduced by up to 5% on units with coated coils.
Extended Warranty - A first year labor - Silver,
and a two year labor - Gold, are available.
Dirty Filter Indicator - A factory installed option
that measures the difference in pressure across
the internal filter and illuminates a LED when the
pressure exceeds the desired difference.
Single Point Power Entry - A field installed
option that allows a single power entry into the air
conditioner. Single point power entry should only be
selected when the air conditioner has two electrical
circuits. See the Summary Ratings Charts for units
with two electrical circuits.
Phase Monitor - Monitors 3Ø power supply and will